Calcium Assays and Indicators

Calcium indicators, molecules that exhibit an increase in fluorescence upon binding Ca²⁺, can be used to measure the activity of GPCRs and more.

Calcium Flux Assays and Calcium Indicators

Extensive research, including seminal contributions by ION’s principal scientists, has afforded a host of excellent, cell-compatible calcium sensors. These molecules are small, synthetic fluorochromes which incorporate a Ca²⁺-binding moiety with excellent selectivity for Ca²⁺ over other physiologically relevant divalent cations, e.g. Mg²⁺. Under conditions where Ca²⁺ is not bound, the fluorescence of the sensor is significantly quenched. When Ca²⁺ is bound, the quenching is relieved, and the fluorescence of the sensor dramatically increases. For some sensors, binding Ca²⁺ also results in a change in the spectral properties of the indicator. For instance, in the case of Fura-2 (below), binding of Ca²⁺ results in a shift of the indicator’s excitation spectrum from a peak at 380 nm in the Ca²⁺ free form to 340 nm in the Ca²⁺-bound form. These indicators are often used in “ratiometric” mode where the Ca²⁺ binding-dependent changes in spectral properties provide a means to control things like photo-bleaching of the indicator and variable optical path length through samples.

Calcium-sensitive fluorescent indicators are compatible with a wide variety of detectors including fluorescent microscopes, plate readers, flow cytometers, and fluorescent indicator-doped solid-state sensors. Over the last 30 years, Ca²⁺-sensitive indicators have been used to conduct calcium mobilization assays across a wide spectrum of cell-based research. Calcium assays have found numerous uses ranging from high-spatial resolution imaging of synaptic activity to high-throughput measurements of G protein-coupled receptor (GPCR) activation-evoked increases in intracellular Ca²⁺ for drug discovery. 

Selecting a fluorescent calcium indicator

Choosing the correct indicator is crucial to the success of an experiment. A number of factors play a role in the decision including the indicator’s wavelength, its Ca²⁺ affinity as well as its cellular loading, retention and localization. ION provides a variety of the most popular and useful fluorescent Ca²⁺ sensors, reagents, and calcium assay kits to help facilitate your research.

 

calcium indicators sticker
Fluorescence images of Fluo-4 stained cells before and after the addition of ionomycin

HeLa cells loaded with Fluo-4 in the presence (+) or the absence (-) of 500 nM of the Ca²⁺  ionophore ionomycin.

Calcium indicator forms and formats 

We provide our calcium dyes in a number of formats to best suit the intended application including membrane permeable forms, membrane impermeable forms and indicators packaged with other key reagents into calcium assay kits that are optimized and validated to ensure excellent performance.

Calcium Assay Kits

While fluorescent Ca²⁺-sensitive indicators have been in widespread use for decades, not every investigator is familiar with the most up-to-date protocols and additional reagents that may be necessary for their effective use. Therefore, ION provides customers with the option to purchase all reagents commonly used to load our Ca²⁺-sensitive fluorescent indicators into most cell types with clear, easy-to-follow instructions to facilitate successful use of fluorescent, Ca²⁺ sensitive indicators in one convenient package. These Brilliant kits are supplied in a variety of sizes ranging from trial packs to the largest-scale HTS (inquire).

Our Flex kit provides all necessary reagents in a format to maximize flexibility for your assay design and customization challenges. Brilliant Calcium Flex is a (EX 490 nm, EM 515 nm) high-throughput, no wash calcium mobilization assay. The most flexible solution for measuring the activity of GPCRs coupled to intracellular Ca²⁺ release. 10 plates

Ratiometric Calcium Essentials kit provides the necessary reagents for conducting no wash, ratiometric calcium flux assays compatible with plate reader and fluorescence microscopy applications. Individual components are provided to give the user the flexibility needed to customize your assay. 

(EX 340/380 nm, EM 505 nm, Kd 145nM) High-throughput, no wash ratiometric calcium (Ca²⁺) assay. No wash, compatible with plate reader and fluorescence microscopy applications.

(EX 525 nm, EM 550 nm, Kd 400nM) Brilliant Calcium Gold is a calcium flux assay for multi-well plate-based, high throughput measurements of calcium mobilization mediated through a wide variety of plasma membrane and intracellular calcium channels. The kit includes our Fluo-Gold dye, which is red-shifted for compatibility with GFP and other green fluorescent indicators. 10 plates

Single wavelength calcium indicators

These are the most popular forms of fluorescent Ca²⁺-sensitive indicators. They possess a range of Ca²⁺ affinities and the broadest instrument compatibility. We offer indicators with spectral properties well matched to common fluorescence microscopes, plate readers and flow cytometers using the most widely available FITC-compatible optics (Fluo-2, Fluo-3 and Fluo-4) while excitation sources and filters for Texas Red are compatible with ICR-1.  

(EX 490 nm/Em 515 nm, Kd 355 nM) is the most used and the most trusted of the single-wavelength Ca²⁺ indicators. It has been the indicator of choice for countless basic research studies and has been used to screen many tens-of-millions of compounds using high-throughput screening (HTS) to discover pharmacological tools and drugs for GPCRs, and a wide variety of Ca²⁺ permeable ion channels and transporters.

(EX 505 nm/Em 525 nm, Kd 390 nM) is a structurally related predecessor of Fluo-4 which has slightly lower affinity for Ca²⁺ and a slightly red-shifted excitation and emission spectrum. For nearly 10 years it was the most commonly used single wavelength, Ca²⁺ sensor. In most cell types Fluo-4 and Fluo-2 show superior loading compared to Fluo-3, however, some have reported that Fluo-3 is superior in certain instances.

(EX 490 nm/Em 515 nm, Kd 290 nM) Also known as Fluo-2 HA, Fluo-2 offers the same spectral properties as Fluo-4 combined with superior loading in many cell types as well as a slightly higher Ca²⁺ affinity. The improved loading and increased affinity can result in superior sensitivity. 

(EX 525 nm/Em 550 nm, Kd 400 nM) Fluo-Gold is a gold fluorescent, intracellular calcium indicator. Designed to measure intracellular calcium flux in high throughput screening and fluorescence microscopy applications. Fluo-Gold’s red-shifted excitation and emission enable multiplexing with GFP-expressing cells or other green fluorescent indicators and minimizes interference from green-fluorescent compounds. 

(EX 580 nm/Em 660 nm, Kd 480 nM) represents a new generation of long sought after fluorescent Ca²⁺ indicators that emit in the red portion of the spectrum. Because of ICR-1’s unique true-red spectral properties, it provides deeper tissue penetration and dramatic background reduction in tissues that have high autofluorescence, in the presence of serum or fluorescent compounds. ICR-1 is also particularly well-suited for use with the most common fluorescent proteins (e.g. GFP/YFP) as well as many optogenetic tools. Unlike some previous red-emitting Ca²⁺-sensitive indicators (e.g. Rhod-2) that concentrate in the mitochondria, ICR-1 enjoys a predominantly cytoplasmic localization similar to the Fluo family of indicators, making it ideal for most intracellular Ca²⁺ measurements.

Dual wavelength calcium indicators

These indicators are particularly useful when more accurate qualification of Ca²⁺ concentrations is desired. However, to utilize the benefits of ratiometric imaging, an instrument (e.g. fluorescence microscope) capable of rapid wavelength switching is required. In the case of Fura-2 (below) an excitation source and optics compatible with 340 nm and 380 nm illumination and ultraviolet (UV) light-compatible sample containers (e.g. microscope slides) are required.

(Ex 340/380 nm/505 nm, Kd 145 nM) is by far the mostly commonly used dual-wavelength excitation Ca²⁺-sensitive fluorescent indicator. While Fura-2’s affinity for Ca²⁺ is higher than any of the single wavelength indicators described above, it is still well-suited to measuring changes in cytoplasmic Ca²⁺ under most conditions while enjoying the benefits of ratiometry.

(Ex 340/380 nm/505 nm, Kd 145 nM) With spectral properties identical to Fura-2, we also offer Fura-2 LR, a leakage-resistant variant. Fura-2 LR is better retained in some cell lines and may provide superior results in cases where intracellular dye retention is needed.

Cell permeable, acetoxymethyl group (AM) esters

When first introduced, loading the highly negatively charged Ca²⁺-sensitive fluorescent indicators was very challenging as they existed only as highly negatively charged, membrane impermeable salts. However, the development of forms of these molecules where the negative charges are masked by non-polar esters-linked moieties (AM esters) allow the molecules to enter cells through passive diffusion. An additional advantage of the AM form is that they are also non-fluorescent and non-Ca²⁺ binding. Once inside the cell, ubiquitous intracellular esterase enzymes promote rapid hydrolysis of the AM esters leaving the active, highly polar form of the indicator trapped inside the cell. 

Reagents for improving indicator loading, retention and background suppression

Although the AM forms of ION’s fluorescent Ca²⁺ indicators readily cross the plasma membrane, there are other factors that can affect how well the indicators load into cells. Because AM forms of the indicators are quite hydrophobic, it is common to use the non-ionic surfactant, Pluronic F-127, to improve their solubility in aqueous solution thus improving their loading into cells. Pluronic F-127 at the concentrations employed for loading indicators into cells is generally well tolerated. While Pluronic F-127 isn’t absolutely essential for loading most fluorescent Ca²⁺ indicators into cells, it is highly recommended. 

Another factor that can affect cell loading and intracellular localization is the presence of transport proteins capable of transporting many ion-sensitive, fluorescent indicators. In many cell types, the activity of these transporters can result in compartmentalization of the indicators into intracellular compartments as well as extrusion of the indicators outside of the cell. Both of these processes can dramatically reduce the signal-to-background levels and in some cell types (e.g. CHO cells),  make adequate loading of Ca²⁺-selective fluorescent indicators nearly impossible. Fortunately, inhibitors of these transport proteins can be an effective means of improving cytoplasmic localization and indicator retention. ION offers a convenient, 100X ION-Pro inhibitor solution that may be used in conjunction with any of our Ca²⁺-sensitive fluorescent indicators.

Be Brilliant! Explore our line of Calcium Assays and Indicators

Filters Sort results
Reset Apply
Product Image
Product
Description
Ex/Em (nm)
Kd (nM)
Price
Quanitity
Add to Order
BAPTA AM packaging with calcium chelator sticker, red background
BAPTA AM is a non-fluorescent calcium chelator. Membrane-permeable. Commonly used for intracellular calcium calibrations.
250
$105.00
Max:
Min: 1
Step: 1
High-throughput, no wash calcium (Ca²⁺) assay. An optimal solution for measuring intracellular Ca²⁺ dynamics, including effectors such as GPCRs and protein transporters. 100 plates
490/515
$3,069.00
Max:
Min: 1
Step: 1
Brilliant calcium assay flex packaging, red background
High-throughput, no wash calcium (Ca²⁺) assay. An optimal solution for measuring intracellular Ca²⁺ dynamics, including effectors such as GPCRs and protein transporters. 10 plates
490/515
$182.00-$399.00
Max:
Min: 1
Step: 1
Brilliant calcium gold, calcium mobilization assay product packaging
ION Biosciences Brilliant Calcium Gold Assay is a total assay solution for multi-well plate-based, high-throughput measurements of Ca²⁺ mobilization mediated through a wide-variety of plasma membrane and intracellular calcium channels. The kit includes our Fluo-Gold dye (Ex/Em: 525/550 nm), which is red-shifted for compatibility with GFP and other green fluorescent indicators.
524/552
$182.00-$399.00
Max:
Min: 1
Step: 1
Fluo-2 AM, a calcium indicator, packaging
Fluo-2 AM is a green fluorescent, calcium indicator. Membrane-permeable. Higher calcium affinity than Fluo-4, with superior intracellular loading.
490/515
290
$69.00-$144.00
Max:
Min: 1
Step: 1
Green fluorescent, calcium (Ca²⁺) indicator, membrane impermeable. Higher Ca²⁺ affinity than Fluo-4
490/515
290
$150.00
Max:
Min: 1
Step: 1
Fluo-3 AM calcium indicator packaging, red background
Fluo-3 AM is a green fluorescent, calcium indicator. Membrane-permeable.
505/525
390
$78.00-$173.00
Max:
Min: 1
Step: 1
Green fluorescent, calcium (Ca²⁺) indicator, membrane impermeable
505/525
390
$161.00
Max:
Min: 1
Step: 1
Fluo-4 AM calcium indicator packaging, red background
Fluo-4 is a green fluorescent, calcium indicator. Membrane-permeable. A popular solution for high-throughput calcium flux assays and GPCR assays. 
490/515
355
$68.00-$147.00
Max:
Min: 1
Step: 1
Fluo-4 AM Ultrapure calcium indicator packaging, red background
Fluo-4 AM Ultrapure is our highest purity (>98%) grade available. Fluo-4 Ultrapure is the same green fluorescent, calcium indicator you've trusted for decades, with minimal impurities to give you maximum confidence. Membrane-permeable. The most popular solution for high-throughput calcium flux assays and GPCR assays
490/515
355
$75.00-$162.00
Max:
Min: 1
Step: 1
Green fluorescent, calcium (Ca²⁺) indicator, membrane impermeable
490/515
355
$147.00
Max:
Min: 1
Step: 1
Fluo gold, calcium indicator for calcium flux assay product packaging
Fluo-Gold is a gold fluorescent (Ex/Em = 525/550 nm), intracellular calcium indicator. Designed to measure intracellular calcium flux in high throughput screening and fluorescence microscopy applications. Fluo-Gold’s red-shifted excitation and emission enable multiplexing with GFP-expressing cells or other green fluorescent indicators, and minimizes interference from green-fluorescent compounds.
528/548
400
$88.00-$198.00
Max:
Min: 1
Step: 1
Fura-2 AM ratiometric calcium indicator packaging, red background
UV-excitable, ratiometric green calcium (Ca²⁺) indicator, membrane permeable
340,380/505
145
$110.00
Max:
Min: 1
Step: 1
Ratiometric calcium (Ca²⁺) indicator, membrane impermeable
340,380/505
145
$110.00
Max:
Min: 1
Step: 1
Fura-2 LR (leakage resistant) AM packaging with calcium (Ca2+) ion sticker, transparent background
Leakage-resistant, ratiometric calcium (Ca²⁺) indicator, membrane permeable
340,380/505
145
$78.00-$173.00
Max:
Min: 1
Step: 1
Leakage-resistant, ratiometric calcium (Ca²⁺) indicator, membrane impermeable
340,380/505
145
$173.00
Max:
Min: 1
Step: 1
ICR-1, a red calcium indicator, packaging
Red fluorescent, calcium (Ca²⁺) indicator, membrane permeable. Optimal for multiplexing and tissue imaging. Fluorescence lifetime and multiphoton compatible.
580/660
480
$160.00-$352.00
Max:
Min: 1
Step: 1
Red fluorescent, calcium (Ca²⁺) indicator, membrane impermeable. Optimal for multiplexing and tissue imaging. Fluorescence lifetime and multiphoton compatible.
580/660
480
$303.00
Max:
Min: 1
Step: 1
Ratiometric calcium assay kit, using Fura-2 AM, packaging
Combines Fura-2 AM with the necessary reagents for conducting no wash, ratiometric calcium flux assays compatible with plate reader and fluorescence microscopy applications. Individual components are provided to give you the flexibility needed to customize your assay.
340,380/505
145
$170.00-$374.00
Max:
Min: 1
Step: 1
0