<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>SQT1 &#8211; ION Biosciences</title>
	<atom:link href="https://ionbiosciences.com/tag-product/sqt1/feed/" rel="self" type="application/rss+xml" />
	<link>https://ionbiosciences.com</link>
	<description>Fluorescent Ion Indicators &#124; Assay Kits</description>
	<lastBuildDate>Wed, 29 Oct 2025 16:39:40 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.0.4</generator>

<image>
	<url>https://ionbiosciences.com/wp-content/uploads/ION-Bio-100x100.png</url>
	<title>SQT1 &#8211; ION Biosciences</title>
	<link>https://ionbiosciences.com</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>CHO K1 Kv11.1 (hERG) Recombinant Cell Line</title>
		<link>https://ionbiosciences.com/store/chok1-kv11-1-herg-cell-line/</link>
					<comments>https://ionbiosciences.com/store/chok1-kv11-1-herg-cell-line/#respond</comments>
		
		<dc:creator><![CDATA[Manuel Pacheco]]></dc:creator>
		<pubDate>Wed, 17 Jul 2024 14:19:06 +0000</pubDate>
				<guid isPermaLink="false">https://ionbiosciences.com/?post_type=product&#038;p=32850</guid>

					<description><![CDATA[<span style="font-weight: 400;"> A stable CHO cell line overexpressing hERG potassium channels for studying Kv11.1 pharmacology and safety screening. </span>

<span style="color: #3490ce;">Be sure to check out our <strong><a href="https://ionbiosciences.com/store/brilliant-thallium-assay" target="_blank" rel="noopener">Brilliant Thallium Assay</a></strong> and or <a href="https://ionbiosciences.com/store/thallium-free-herg-potassium-channel-assay/" target="_blank" rel="noopener"><strong>Thallium-free hERG Potassium Channel Assay</strong></a> for high throughput formatted kits, suitable for voltage-gated potassium channels</span>

&#160;

&#160;]]></description>
										<content:encoded><![CDATA[		<div data-elementor-type="product-post" data-elementor-id="32850" class="elementor elementor-32850" data-elementor-post-type="product">
				<div class="elementor-element elementor-element-3fc7b9e2 e-flex e-con-boxed e-con e-parent" data-id="3fc7b9e2" data-element_type="container">
					<div class="e-con-inner">
		<div class="elementor-element elementor-element-b8714ce e-con-full e-flex e-con e-child" data-id="b8714ce" data-element_type="container">
		<div class="elementor-element elementor-element-e790e88 e-con-full e-flex e-con e-child" data-id="e790e88" data-element_type="container">
				<div class="elementor-element elementor-element-5f34a1b0 elementor-widget elementor-widget-text-editor" data-id="5f34a1b0" data-element_type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
									<p><span style="font-weight: 400;">Our </span><b>CHO-K1 Kv11.1 (hERG) Recombinant Cell Line</b><span style="font-weight: 400;"> is a high-performance, stably expressing cell for cardiotoxicity screening and hERG drug discovery. Validated using fluorescence-based assays, like Brilliant Thallium Assay, and </span><b>Automated Patch Clamp (APC)</b><span style="font-weight: 400;"> platforms, including the </span><b>SyncroPatch 384</b><span style="font-weight: 400;">, this essential cell line provides complete coverage for your hERG screening needs.</span></p><p><span style="font-weight: 400;">hERG channels (</span><b>Kv11.1, KCNH2</b><span style="font-weight: 400;">) are essential for </span><b>cardiac repolarization</b><span style="font-weight: 400;">, and their inhibition is a primary concern in </span><b>drug safety assessment</b><span style="font-weight: 400;"> due to the risk of </span><b>long QT syndrome</b><span style="font-weight: 400;"> and potential </span><b>fatal arrhythmias</b><span style="font-weight: 400;">. Given the FDA&#8217;s stringent </span><b>CiPA (Comprehensive in Vitro Proarrhythmia Assay) guidelines</b><span style="font-weight: 400;">, rigorous hERG screening is a </span><b>critical step in drug development</b><span style="font-weight: 400;"> to identify off-target cardiac effects.</span></p>								</div>
				</div>
				</div>
		<div class="elementor-element elementor-element-63f39d4 e-con-full e-flex e-con e-child" data-id="63f39d4" data-element_type="container">
				<div class="elementor-element elementor-element-9fe0742 elementor-widget elementor-widget-heading" data-id="9fe0742" data-element_type="widget" data-widget_type="heading.default">
				<div class="elementor-widget-container">
					<h4 class="elementor-heading-title elementor-size-default">Key Features &amp; Applications</h4>				</div>
				</div>
				<div class="elementor-element elementor-element-d7e83b0 elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list" data-id="d7e83b0" data-element_type="widget" data-widget_type="icon-list.default">
				<div class="elementor-widget-container">
							<ul class="elementor-icon-list-items">
							<li class="elementor-icon-list-item">
											<span class="elementor-icon-list-icon">
							<i aria-hidden="true" class="fas fa-angle-right"></i>						</span>
										<span class="elementor-icon-list-text"><b>Validated for Automated Patch Clamp </b>– Compatible with high-throughput electrophysiology platforms like <b>SyncroPatch 384</b></span>
									</li>
								<li class="elementor-icon-list-item">
											<span class="elementor-icon-list-icon">
							<i aria-hidden="true" class="fas fa-angle-right"></i>						</span>
										<span class="elementor-icon-list-text"><b>High-Quality Ion Channel Expression </b>– Reliable Kv11.1 (hERG) expression with industry-standard pharmacological response</span>
									</li>
								<li class="elementor-icon-list-item">
											<span class="elementor-icon-list-icon">
							<i aria-hidden="true" class="fas fa-angle-right"></i>						</span>
										<span class="elementor-icon-list-text"><b>Ideal for Cardiac Safety &amp; Drug Discovery </b>– Supports <b>electrophysiology-based assays, fluorescence-based screening (e.g., thallium flux assays), and CiPA-compliant testing</b></span>
									</li>
								<li class="elementor-icon-list-item">
											<span class="elementor-icon-list-icon">
							<i aria-hidden="true" class="fas fa-angle-right"></i>						</span>
										<span class="elementor-icon-list-text"><b>Broad Applications Beyond Cardiac Screening </b>– hERG channels are also implicated in <b>schizophrenia, tumor proliferation, cell migration, and apoptosis</b>, expanding their relevance beyond cardiotoxicity studies</span>
									</li>
						</ul>
						</div>
				</div>
				</div>
				</div>
				<div class="elementor-element elementor-element-a14d863 elementor-widget elementor-widget-heading" data-id="a14d863" data-element_type="widget" data-widget_type="heading.default">
				<div class="elementor-widget-container">
					<h4 class="elementor-heading-title elementor-size-default">Optimized for Industry-Standard Drug Screening</h4>				</div>
				</div>
				<div class="elementor-element elementor-element-0a7f156 elementor-widget elementor-widget-text-editor" data-id="0a7f156" data-element_type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
									<p><span style="font-weight: 400;">Using this cell line in </span><b>high-throughput electrophysiology and fluorescence assays</b><span style="font-weight: 400;"> allows for </span><b>precise IC₅₀ determinations</b><span style="font-weight: 400;"> of known hERG inhibitors, ensuring alignment with regulatory expectations and literature benchmarks. Recent </span><b>pharmacological validation with Bepridil, Diltiazem, Ranolazine, and Verapamil</b><span style="font-weight: 400;"> confirmed its reliability in predicting </span><b>hERG-related drug interactions</b><span style="font-weight: 400;"> across multiple assay formats and temperature conditions.</span></p><p><span style="font-weight: 400;">Ensure your </span><b>cardiac safety and ion channel screening</b><span style="font-weight: 400;"> workflows are backed by the highest-quality recombinant hERG cell line.</span></p>								</div>
				</div>
				<div class="elementor-element elementor-element-2948821 elementor-widget elementor-widget-image" data-id="2948821" data-element_type="widget" data-widget_type="image.default">
				<div class="elementor-widget-container">
															<img fetchpriority="high" decoding="async" width="800" height="523" src="https://ionbiosciences.com/wp-content/uploads/Kv11.1-hERG-cell-line-1024x669.webp" class="attachment-large size-large wp-image-32866" alt="Representative hERG assay data for high-throughput screening of Kv11.1 modulators, such as terfenadine." srcset="https://ionbiosciences.com/wp-content/uploads/Kv11.1-hERG-cell-line-1024x669.webp 1024w, https://ionbiosciences.com/wp-content/uploads/Kv11.1-hERG-cell-line-300x196.webp 300w, https://ionbiosciences.com/wp-content/uploads/Kv11.1-hERG-cell-line-768x502.webp 768w, https://ionbiosciences.com/wp-content/uploads/Kv11.1-hERG-cell-line-600x392.webp 600w, https://ionbiosciences.com/wp-content/uploads/Kv11.1-hERG-cell-line.webp 1296w" sizes="(max-width: 800px) 100vw, 800px" />															</div>
				</div>
				<div class="elementor-element elementor-element-5eb3b96 elementor-widget elementor-widget-text-editor" data-id="5eb3b96" data-element_type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
									<p><span style="font-weight: 400;">Our hERG-expressing CHO K1 cells were </span><span style="font-weight: 400;">also validated with automated electrophysiology using the SyncroPatch 384 from Nanion Technologies, </span><span style="font-weight: 400;">highlighting ION’s CHO K1 hERG cell line is an excellent tool for cardiac safety profiling.</span></p>								</div>
				</div>
		<div class="elementor-element elementor-element-ce07c51 e-con-full e-flex e-con e-child" data-id="ce07c51" data-element_type="container">
		<div class="elementor-element elementor-element-cfebb16 e-con-full e-flex e-con e-child" data-id="cfebb16" data-element_type="container">
				<div class="elementor-element elementor-element-192fb25 elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list" data-id="192fb25" data-element_type="widget" data-widget_type="icon-list.default">
				<div class="elementor-widget-container">
							<ul class="elementor-icon-list-items">
							<li class="elementor-icon-list-item">
											<span class="elementor-icon-list-icon">
							<i aria-hidden="true" class="fas fa-angle-right"></i>						</span>
										<span class="elementor-icon-list-text">High success rates (96%) for cells with R Seal &gt;500MΩ.</span>
									</li>
								<li class="elementor-icon-list-item">
											<span class="elementor-icon-list-icon">
							<i aria-hidden="true" class="fas fa-angle-right"></i>						</span>
										<span class="elementor-icon-list-text">Results agree with reported literature values.</span>
									</li>
								<li class="elementor-icon-list-item">
											<span class="elementor-icon-list-icon">
							<i aria-hidden="true" class="fas fa-angle-right"></i>						</span>
										<span class="elementor-icon-list-text">Patch stable for &gt;10 min, and compatible with room and physiological temperature recordings.</span>
									</li>
						</ul>
						</div>
				</div>
				<div class="elementor-element elementor-element-7ad1af3 elementor-widget elementor-widget-tp-button" data-id="7ad1af3" data-element_type="widget" data-widget_type="tp-button.default">
				<div class="elementor-widget-container">
					<div class="pt-plus-button-wrapper   text-left text--mobilecenter   "><div class="button_parallax   " ><div id="button6aa5b9e718ff6"  class=" text-left text--mobilecenter ts-button content_hover_effect content_hover_grow  " ><div class="pt_plus_button btn6aa5b9e718fb6 button-style-13  hover-left   "  ><div class="animted-content-inner "><a href="https://ionbiosciences.com/wp-content/uploads/application-note-herg-cell-line-nanion-synchropatch384.pdf.pdf" target="_blank" class="button-link-wrap " role="button" data-hover="Read the full application note here"  ><span>Read the full application note here<i class="btn-icon button-after fa fa-chevron-right"></i></span></a></div></div></div></div></div>				</div>
				</div>
				</div>
		<div class="elementor-element elementor-element-0d3e684 e-con-full e-flex e-con e-child" data-id="0d3e684" data-element_type="container">
				<div class="elementor-element elementor-element-1df82e6 elementor-widget elementor-widget-image" data-id="1df82e6" data-element_type="widget" data-widget_type="image.default">
				<div class="elementor-widget-container">
															<img decoding="async" width="800" height="499" src="https://ionbiosciences.com/wp-content/uploads/table-IC-values.webp" class="attachment-large size-large wp-image-33681" alt="" srcset="https://ionbiosciences.com/wp-content/uploads/table-IC-values.webp 1024w, https://ionbiosciences.com/wp-content/uploads/table-IC-values-300x187.webp 300w, https://ionbiosciences.com/wp-content/uploads/table-IC-values-768x479.webp 768w, https://ionbiosciences.com/wp-content/uploads/table-IC-values-600x374.webp 600w" sizes="(max-width: 800px) 100vw, 800px" />															</div>
				</div>
				</div>
				</div>
					</div>
				</div>
				</div>
		]]></content:encoded>
					
					<wfw:commentRss>https://ionbiosciences.com/store/chok1-kv11-1-herg-cell-line/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
	</channel>
</rss>
