<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Blog &#8211; ION Biosciences</title>
	<atom:link href="https://ionbiosciences.com/resources/blog/feed/" rel="self" type="application/rss+xml" />
	<link>https://ionbiosciences.com</link>
	<description>Fluorescent Ion Indicators &#124; Assay Kits</description>
	<lastBuildDate>Tue, 31 Dec 2024 17:01:43 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.1.5</generator>

<image>
	<url>https://ionbiosciences.com/wp-content/uploads/ION-Bio-100x100.png</url>
	<title>Blog &#8211; ION Biosciences</title>
	<link>https://ionbiosciences.com</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>How to analyze thallium flux assay data</title>
		<link>https://ionbiosciences.com/blog/how-to-analyze-thallium-flux-assay-data-a-step-by-step-guide/</link>
		
		<dc:creator><![CDATA[Manuel Pacheco]]></dc:creator>
		<pubDate>Mon, 12 Feb 2024 01:31:33 +0000</pubDate>
				<category><![CDATA[Blog]]></category>
		<guid isPermaLink="false">https://ionbiosciences.com/?p=27859</guid>

					<description><![CDATA[ A step by step guide]]></description>
										<content:encoded><![CDATA[		<div data-elementor-type="wp-post" data-elementor-id="27859" class="elementor elementor-27859" data-elementor-post-type="post">
				<div class="elementor-element elementor-element-eee0d64 e-con-full e-flex e-con e-parent" data-id="eee0d64" data-element_type="container" data-settings="{&quot;background_background&quot;:&quot;classic&quot;}">
		<div class="elementor-element elementor-element-7691d70 e-con-full e-flex e-con e-child" data-id="7691d70" data-element_type="container">
				<div class="elementor-element elementor-element-7cb522f elementor-widget__width-initial elementor-widget-mobile__width-initial elementor-widget elementor-widget-text-editor" data-id="7cb522f" data-element_type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
									In this short post, we’re going to walk you through how to get from raw to manuscript quality data when using thallium flux assays, including generating dose response curves and calculating EC<sub>50</sub> values.								</div>
				</div>
				<div class="elementor-element elementor-element-675e008 elementor-widget elementor-widget-table-of-contents" data-id="675e008" data-element_type="widget" id="menuBlog" data-settings="{&quot;marker_view&quot;:&quot;bullets&quot;,&quot;icon&quot;:{&quot;value&quot;:&quot;&quot;,&quot;library&quot;:&quot;&quot;},&quot;headings_by_tags&quot;:[&quot;h2&quot;],&quot;no_headings_message&quot;:&quot;No headings were found on this page.&quot;,&quot;hierarchical_view&quot;:&quot;yes&quot;,&quot;min_height&quot;:{&quot;unit&quot;:&quot;px&quot;,&quot;size&quot;:&quot;&quot;,&quot;sizes&quot;:[]},&quot;min_height_tablet&quot;:{&quot;unit&quot;:&quot;px&quot;,&quot;size&quot;:&quot;&quot;,&quot;sizes&quot;:[]},&quot;min_height_mobile&quot;:{&quot;unit&quot;:&quot;px&quot;,&quot;size&quot;:&quot;&quot;,&quot;sizes&quot;:[]}}" data-widget_type="table-of-contents.default">
				<div class="elementor-widget-container">
									<div class="elementor-toc__header">
						<h4 class="elementor-toc__header-title">
				How to analyze thallium flux assay data			</h4>
								</div>
				<div id="elementor-toc__675e008" class="elementor-toc__body">
			<div class="elementor-toc__spinner-container">
				<i class="elementor-toc__spinner eicon-animation-spin eicon-loading" aria-hidden="true"></i>			</div>
		</div>
						</div>
				</div>
				</div>
				<div class="elementor-element elementor-element-cc6fd14 elementor-widget-tablet__width-initial elementor-widget elementor-widget-image" data-id="cc6fd14" data-element_type="widget" data-widget_type="image.default">
				<div class="elementor-widget-container">
																<a href="https://ionbiosciences.com/wp-content/uploads/How-to-analyze-thallium-flux-assay-data-1-3.png" data-elementor-open-lightbox="yes" data-e-action-hash="#elementor-action%3Aaction%3Dlightbox%26settings%3DeyJpZCI6MzI1ODQsInVybCI6Imh0dHBzOlwvXC9pb25iaW9zY2llbmNlcy5jb21cL3dwLWNvbnRlbnRcL3VwbG9hZHNcL3RoYWxsaXVtLWZsdXgtZGF0YS1hbmFseXNpcy1zdW1tYXJ5LnBuZyJ9">
							<img fetchpriority="high" decoding="async" width="800" height="523" src="https://ionbiosciences.com/wp-content/uploads/thallium-flux-data-analysis-summary-1024x670.png" class="attachment-large size-large wp-image-32584" alt="Image displaying raw thallium flux assay data next to a summarized dose response curve" srcset="https://ionbiosciences.com/wp-content/uploads/thallium-flux-data-analysis-summary-1024x670.png 1024w, https://ionbiosciences.com/wp-content/uploads/thallium-flux-data-analysis-summary-300x196.png 300w, https://ionbiosciences.com/wp-content/uploads/thallium-flux-data-analysis-summary-768x503.png 768w, https://ionbiosciences.com/wp-content/uploads/thallium-flux-data-analysis-summary-600x393.png 600w, https://ionbiosciences.com/wp-content/uploads/thallium-flux-data-analysis-summary.png 1296w" sizes="(max-width: 800px) 100vw, 800px" />								</a>
															</div>
				</div>
				</div>
		<div class="elementor-element elementor-element-fc71e10 e-con-full e-flex e-con e-parent" data-id="fc71e10" data-element_type="container" data-settings="{&quot;background_background&quot;:&quot;classic&quot;}">
				<div class="elementor-element elementor-element-d366b40 elementor-widget elementor-widget-heading" data-id="d366b40" data-element_type="widget" id="step" data-widget_type="heading.default">
				<div class="elementor-widget-container">
					<h2 class="elementor-heading-title elementor-size-default"><span class="step">Step 1:</span> Normalization (sometimes called baseline subtraction)</h2>				</div>
				</div>
		<div class="elementor-element elementor-element-d5b15ac e-flex e-con-boxed e-con e-child" data-id="d5b15ac" data-element_type="container">
					<div class="e-con-inner">
		<div class="elementor-element elementor-element-01876c5 e-con-full e-flex e-con e-child" data-id="01876c5" data-element_type="container">
				<div class="elementor-element elementor-element-bcf80ad elementor-widget elementor-widget-text-editor" data-id="bcf80ad" data-element_type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
									Start by defining your baseline (F<sub>0</sub>), which is the average fluorescence (RFU) for each individual well prior to stimulus* addition [*stimulus solutions typically include a compound of interest and thallium sulfate]. The number of data points to choose is going to depend on your read frequency, the time between the start of data collection and your stimulus addition, as well as the stability of your baseline. Although the baseline fluorescence for each well may vary slightly, the variation in the baseline for a given well should be relatively low. Typically the average of the first 5-15 data points is sufficient to generate a flat baseline. In this specific example, we collected 20 data points prior to stimulus addition. Since the baseline fluorescence is stable, choosing anywhere from 5 &#8211; 20 points should not have a significant impact on your normalized data. If you have a noisier baseline, you may consider averaging a larger number of data points.								</div>
				</div>
				</div>
		<div class="elementor-element elementor-element-a7f9179 e-con-full e-flex e-con e-child" data-id="a7f9179" data-element_type="container">
				<div class="elementor-element elementor-element-139aee1 elementor-widget__width-initial elementor-widget elementor-widget-image" data-id="139aee1" data-element_type="widget" data-widget_type="image.default">
				<div class="elementor-widget-container">
																<a href="https://ionbiosciences.com/wp-content/uploads/How-to-analyze-thallium-flux-assay-data-2-3.png" data-elementor-open-lightbox="yes" data-e-action-hash="#elementor-action%3Aaction%3Dlightbox%26settings%3DeyJpZCI6MzI1ODUsInVybCI6Imh0dHBzOlwvXC9pb25iaW9zY2llbmNlcy5jb21cL3dwLWNvbnRlbnRcL3VwbG9hZHNcL3Jhdy1raW5ldGljLXRyYWNlcy5wbmcifQ%3D%3D">
							<img decoding="async" width="1296" height="848" src="https://ionbiosciences.com/wp-content/uploads/raw-kinetic-traces.png" class="elementor-animation-grow attachment-full size-full wp-image-32585" alt="Representative kinetic data from a thallium flux assay with a notated baseline region" srcset="https://ionbiosciences.com/wp-content/uploads/raw-kinetic-traces.png 1296w, https://ionbiosciences.com/wp-content/uploads/raw-kinetic-traces-300x196.png 300w, https://ionbiosciences.com/wp-content/uploads/raw-kinetic-traces-1024x670.png 1024w, https://ionbiosciences.com/wp-content/uploads/raw-kinetic-traces-768x503.png 768w, https://ionbiosciences.com/wp-content/uploads/raw-kinetic-traces-600x393.png 600w" sizes="(max-width: 1296px) 100vw, 1296px" />								</a>
															</div>
				</div>
				</div>
					</div>
				</div>
		<div class="elementor-element elementor-element-c05bb28 e-flex e-con-boxed e-con e-child" data-id="c05bb28" data-element_type="container">
					<div class="e-con-inner">
		<div class="elementor-element elementor-element-99e5f87 e-con-full e-flex e-con e-child" data-id="99e5f87" data-element_type="container" data-settings="{&quot;background_background&quot;:&quot;classic&quot;}">
				<div class="elementor-element elementor-element-322438d elementor-widget elementor-widget-text-editor" data-id="322438d" data-element_type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
									<span style="color: #646464; letter-spacing: 0.4px;">Once you have calculated the F<sub>0</sub> for each well, you divide every data point (F) in that curve by the F<sub>0</sub> value. The end result of the normalization process is a kinetic trace (F/F<sub>0</sub>) where all baselines are equal to 1. This is an important correction to account for well to well variability caused by instrumentation, well position, slight differences in cell density between wells, or other factors (edge wells) that may cause certain wells to have a higher or lower fluorescence than others. Once all your data is normalized, trends that may not have been obvious when looking at your raw data should become more clear.</span>								</div>
				</div>
				</div>
		<div class="elementor-element elementor-element-f08c32b e-con-full e-flex e-con e-child" data-id="f08c32b" data-element_type="container">
				<div class="elementor-element elementor-element-ccd3561 elementor-widget__width-initial elementor-widget elementor-widget-image" data-id="ccd3561" data-element_type="widget" data-widget_type="image.default">
				<div class="elementor-widget-container">
																<a href="https://ionbiosciences.com/wp-content/uploads/How-to-analyze-thallium-flux-assay-data-3-5.png" data-elementor-open-lightbox="yes" data-e-action-hash="#elementor-action%3Aaction%3Dlightbox%26settings%3DeyJpZCI6MzI1ODEsInVybCI6Imh0dHBzOlwvXC9pb25iaW9zY2llbmNlcy5jb21cL3dwLWNvbnRlbnRcL3VwbG9hZHNcL25vcm1hbGl6ZWQta2luZXRpYy10cmFjZXMucG5nIn0%3D">
							<img decoding="async" width="1296" height="848" src="https://ionbiosciences.com/wp-content/uploads/normalized-kinetic-traces.png" class="elementor-animation-grow attachment-full size-full wp-image-32581" alt="Representative normalized data from a thallium flux assay" srcset="https://ionbiosciences.com/wp-content/uploads/normalized-kinetic-traces.png 1296w, https://ionbiosciences.com/wp-content/uploads/normalized-kinetic-traces-300x196.png 300w, https://ionbiosciences.com/wp-content/uploads/normalized-kinetic-traces-1024x670.png 1024w, https://ionbiosciences.com/wp-content/uploads/normalized-kinetic-traces-768x503.png 768w, https://ionbiosciences.com/wp-content/uploads/normalized-kinetic-traces-600x393.png 600w" sizes="(max-width: 1296px) 100vw, 1296px" />								</a>
															</div>
				</div>
				</div>
					</div>
				</div>
				</div>
		<div class="elementor-element elementor-element-0b44223 e-con-full e-flex e-con e-parent" data-id="0b44223" data-element_type="container" data-settings="{&quot;background_background&quot;:&quot;classic&quot;}">
				<div class="elementor-element elementor-element-a6b8ed3 elementor-widget elementor-widget-heading" data-id="a6b8ed3" data-element_type="widget" data-widget_type="heading.default">
				<div class="elementor-widget-container">
					<h2 class="elementor-heading-title elementor-size-default"><span class="step">Step 2: </span>Calculating the slope (or V<sub>max</sub>)
</h2>				</div>
				</div>
		<div class="elementor-element elementor-element-b8edec2 e-flex e-con-boxed e-con e-child" data-id="b8edec2" data-element_type="container">
					<div class="e-con-inner">
		<div class="elementor-element elementor-element-748462d e-con-full e-flex e-con e-child" data-id="748462d" data-element_type="container">
				<div class="elementor-element elementor-element-df6ac82 elementor-widget elementor-widget-text-editor" data-id="df6ac82" data-element_type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
									<p>As the name suggests, thallium flux assays are designed to provide information about the activity of a potassium channel* based on the rate of thallium influx into your cells [*thallium flux assays can also be used for sodium channels, monovalent cation transporters, and G<sub>i/o</sub> GPCRs.] The more open channels there are on a cell membrane, the faster thallium ions will enter into a cell. Alternatively, if channels are inhibited or blocked, the rate of thallium entry into a cell will be reduced. Therefore, to get an accurate measure of ion channel activity, the best approach is almost always to calculate the slope (or V<sub>max</sub>) of each normalized kinetic trace as soon after the addition of stimulus as possible.</p>								</div>
				</div>
				</div>
		<div class="elementor-element elementor-element-cceea6c e-con-full e-flex e-con e-child" data-id="cceea6c" data-element_type="container">
				<div class="elementor-element elementor-element-5490cc8 elementor-widget__width-initial elementor-widget elementor-widget-image" data-id="5490cc8" data-element_type="widget" data-widget_type="image.default">
				<div class="elementor-widget-container">
																<a href="https://ionbiosciences.com/wp-content/uploads/How-to-analyze-thallium-flux-assay-data-4-3.png" data-elementor-open-lightbox="yes" data-e-action-hash="#elementor-action%3Aaction%3Dlightbox%26settings%3DeyJpZCI6MzI1ODYsInVybCI6Imh0dHBzOlwvXC9pb25iaW9zY2llbmNlcy5jb21cL3dwLWNvbnRlbnRcL3VwbG9hZHNcL25vcm1hbGl6ZWQta2luZXRpYy10cmFjZXMtd2l0aC1zbG9wZS5wbmcifQ%3D%3D">
							<img loading="lazy" decoding="async" width="1296" height="848" src="https://ionbiosciences.com/wp-content/uploads/normalized-kinetic-traces-with-slope.png" class="elementor-animation-grow attachment-full size-full wp-image-32586" alt="Displayed Vmax values (slopes) for thallium flux kinetic data for different drug concentrations." srcset="https://ionbiosciences.com/wp-content/uploads/normalized-kinetic-traces-with-slope.png 1296w, https://ionbiosciences.com/wp-content/uploads/normalized-kinetic-traces-with-slope-300x196.png 300w, https://ionbiosciences.com/wp-content/uploads/normalized-kinetic-traces-with-slope-1024x670.png 1024w, https://ionbiosciences.com/wp-content/uploads/normalized-kinetic-traces-with-slope-768x503.png 768w, https://ionbiosciences.com/wp-content/uploads/normalized-kinetic-traces-with-slope-600x393.png 600w" sizes="auto, (max-width: 1296px) 100vw, 1296px" />								</a>
															</div>
				</div>
				</div>
					</div>
				</div>
				<div class="elementor-element elementor-element-135cd71 elementor-widget elementor-widget-text-editor" data-id="135cd71" data-element_type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
									To calculate the slope, you typically want to pick a range between 1-20 seconds after the addition of your stimulus solution and conduct a simple linear regression. The calculated slope is also referred to as V<sub>max</sub> (units/sec). As you can see in the plot below, the slope of F/F<sub>0</sub> starts to decrease as intracellular thallium approaches tonic equilibrium. For this assay specifically, that downturn starts to occur within the first 15 seconds after stimulus addition, so we elected to calculate the slope using the first 10 data points after stimulus addition. A value in this range is usually sufficient for most assays, but may not be ideal if there are baseline anomalies from stimulus addition or if your influx rate is significantly faster. In these cases, choose a range that makes sense for your data.								</div>
				</div>
				</div>
		<div class="elementor-element elementor-element-098799c e-con-full e-flex e-con e-parent" data-id="098799c" data-element_type="container" data-settings="{&quot;background_background&quot;:&quot;classic&quot;}">
				<div class="elementor-element elementor-element-70e321b elementor-widget elementor-widget-heading" data-id="70e321b" data-element_type="widget" data-widget_type="heading.default">
				<div class="elementor-widget-container">
					<h2 class="elementor-heading-title elementor-size-default"><span class="step">Step 3:</span> Using V<sub>max</sub> to generate a dose response curve</h2>				</div>
				</div>
		<div class="elementor-element elementor-element-97a9e3d e-flex e-con-boxed e-con e-child" data-id="97a9e3d" data-element_type="container">
					<div class="e-con-inner">
		<div class="elementor-element elementor-element-3c6555b e-con-full e-flex e-con e-child" data-id="3c6555b" data-element_type="container">
				<div class="elementor-element elementor-element-cad1aac elementor-widget elementor-widget-text-editor" data-id="cad1aac" data-element_type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
									After V<sub>max</sub> has been calculated for each kinetic trace, create a plot of V<sub>max</sub>  (y-axis) versus the log of your compound concentration (x-axis). The standard deviation for each concentration can be calculated from the V<sub>max</sub>  values for replicates, and are usually used to generate y-axis error bars.								</div>
				</div>
				</div>
		<div class="elementor-element elementor-element-4f8cdb7 e-con-full e-flex e-con e-child" data-id="4f8cdb7" data-element_type="container">
				<div class="elementor-element elementor-element-05cbbd0 elementor-widget__width-initial elementor-widget elementor-widget-image" data-id="05cbbd0" data-element_type="widget" data-widget_type="image.default">
				<div class="elementor-widget-container">
																<a href="https://ionbiosciences.com/wp-content/uploads/How-to-analyze-thallium-flux-assay-data-5-2.png" data-elementor-open-lightbox="yes" data-e-action-hash="#elementor-action%3Aaction%3Dlightbox%26settings%3DeyJpZCI6MzI1ODIsInVybCI6Imh0dHBzOlwvXC9pb25iaW9zY2llbmNlcy5jb21cL3dwLWNvbnRlbnRcL3VwbG9hZHNcL2RvcGFtaW5lLWNvbmNlbnRyYXRpb24tcmVzcG9uc2UtY3VydmUucG5nIn0%3D">
							<img loading="lazy" decoding="async" width="1296" height="848" src="https://ionbiosciences.com/wp-content/uploads/dopamine-concentration-response-curve.png" class="elementor-animation-grow attachment-full size-full wp-image-32582" alt="Dose response curve for the dopamine receptor D2, a Gi GPCR assay" srcset="https://ionbiosciences.com/wp-content/uploads/dopamine-concentration-response-curve.png 1296w, https://ionbiosciences.com/wp-content/uploads/dopamine-concentration-response-curve-300x196.png 300w, https://ionbiosciences.com/wp-content/uploads/dopamine-concentration-response-curve-1024x670.png 1024w, https://ionbiosciences.com/wp-content/uploads/dopamine-concentration-response-curve-768x503.png 768w, https://ionbiosciences.com/wp-content/uploads/dopamine-concentration-response-curve-600x393.png 600w" sizes="auto, (max-width: 1296px) 100vw, 1296px" />								</a>
															</div>
				</div>
				</div>
					</div>
				</div>
				</div>
		<div class="elementor-element elementor-element-b4f449e e-con-full e-flex e-con e-parent" data-id="b4f449e" data-element_type="container" data-settings="{&quot;background_background&quot;:&quot;classic&quot;}">
				<div class="elementor-element elementor-element-2e65926 elementor-widget elementor-widget-heading" data-id="2e65926" data-element_type="widget" data-widget_type="heading.default">
				<div class="elementor-widget-container">
					<h2 class="elementor-heading-title elementor-size-default"> <span class="step">Step 4:  </span>Calculating an EC<sub>50</sub> value</h2>				</div>
				</div>
		<div class="elementor-element elementor-element-7daecfc e-flex e-con-boxed e-con e-child" data-id="7daecfc" data-element_type="container">
					<div class="e-con-inner">
		<div class="elementor-element elementor-element-47a7662 e-con-full e-flex e-con e-child" data-id="47a7662" data-element_type="container">
				<div class="elementor-element elementor-element-ec732fa elementor-widget elementor-widget-text-editor" data-id="ec732fa" data-element_type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
									An EC<sub>50</sub> value is defined as the concentration of your compound when it reaches 50% of its max effectiveness, and is indicative of a compound’s potency. A lower EC<sub>50</sub> indicates a more potent compound, which is usually preferred in drug discovery. For inhibition assays, an IC<sub>50</sub> is reported instead of an EC<sub>50</sub>.								</div>
				</div>
				</div>
		<div class="elementor-element elementor-element-484c25c e-con-full e-flex e-con e-child" data-id="484c25c" data-element_type="container">
				<div class="elementor-element elementor-element-6289678 elementor-widget__width-initial elementor-widget elementor-widget-image" data-id="6289678" data-element_type="widget" data-widget_type="image.default">
				<div class="elementor-widget-container">
																<a href="https://ionbiosciences.com/wp-content/uploads/How-to-analyze-thallium-flux-assay-data-6-3.png" data-elementor-open-lightbox="yes" data-e-action-hash="#elementor-action%3Aaction%3Dlightbox%26settings%3DeyJpZCI6MzI1ODMsInVybCI6Imh0dHBzOlwvXC9pb25iaW9zY2llbmNlcy5jb21cL3dwLWNvbnRlbnRcL3VwbG9hZHNcL2RvcGFtaW5lLWRvc2UtcmVzcG9uc2UtY3VydmUtZWM1MC5wbmcifQ%3D%3D">
							<img loading="lazy" decoding="async" width="1296" height="848" src="https://ionbiosciences.com/wp-content/uploads/dopamine-dose-response-curve-ec50.png" class="elementor-animation-grow attachment-full size-full wp-image-32583" alt="Dose response curve for the dopamine receptor annotated with EC50 estimate" srcset="https://ionbiosciences.com/wp-content/uploads/dopamine-dose-response-curve-ec50.png 1296w, https://ionbiosciences.com/wp-content/uploads/dopamine-dose-response-curve-ec50-300x196.png 300w, https://ionbiosciences.com/wp-content/uploads/dopamine-dose-response-curve-ec50-1024x670.png 1024w, https://ionbiosciences.com/wp-content/uploads/dopamine-dose-response-curve-ec50-768x503.png 768w, https://ionbiosciences.com/wp-content/uploads/dopamine-dose-response-curve-ec50-600x393.png 600w" sizes="auto, (max-width: 1296px) 100vw, 1296px" />								</a>
															</div>
				</div>
				</div>
					</div>
				</div>
				<div class="elementor-element elementor-element-fc0c31a elementor-widget elementor-widget-text-editor" data-id="fc0c31a" data-element_type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
									<p>To calculate an EC<sub>50</sub> value, apply a 4-parameter, non-linear fit with a variable slope to your dose response curve. Ensure you have chosen the right model for your assay. For example, we used log[agonist] vs. response since our compound increased the activity of our target at higher concentrations.</p>								</div>
				</div>
				</div>
		<div class="elementor-element elementor-element-e31dec4 e-con-full e-flex e-con e-parent" data-id="e31dec4" data-element_type="container" data-settings="{&quot;background_background&quot;:&quot;classic&quot;}">
				<div class="elementor-element elementor-element-c1809f8 elementor-widget__width-initial elementor-widget-mobile__width-initial elementor-widget elementor-widget-text-editor" data-id="c1809f8" data-element_type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
									<p>Fortunately, many software programs today make these steps incredibly simple and some will even do all the work for you. Be mindful that you are using the optimal settings for analyzing your data when relying on software to do all of the processing. If you have any questions, refer to this guide or <a href="https://ionbiosciences.com/contact/">reach out to us</a> for additional troubleshooting tips.</p>								</div>
				</div>
				</div>
				</div>
		]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Navigating the World of Calcium Indicators</title>
		<link>https://ionbiosciences.com/blog/navigating-the-world-of-calcium-indicators-a-comprehensive-guide-for-researchers/</link>
		
		<dc:creator><![CDATA[MDD Investments]]></dc:creator>
		<pubDate>Mon, 05 Feb 2024 22:55:18 +0000</pubDate>
				<category><![CDATA[Blog]]></category>
		<guid isPermaLink="false">https://ionbiosciences.com/?p=32427</guid>

					<description><![CDATA[ A Comprehensive Guide for Researchers]]></description>
										<content:encoded><![CDATA[		<div data-elementor-type="wp-post" data-elementor-id="32427" class="elementor elementor-32427" data-elementor-post-type="post">
				<div class="elementor-element elementor-element-195f4e7 e-con-full e-flex e-con e-parent" data-id="195f4e7" data-element_type="container" data-settings="{&quot;background_background&quot;:&quot;classic&quot;}">
		<div class="elementor-element elementor-element-2488254 e-con-full e-flex e-con e-child" data-id="2488254" data-element_type="container">
				<div class="elementor-element elementor-element-1c2be94 elementor-widget elementor-widget-table-of-contents" data-id="1c2be94" data-element_type="widget" data-settings="{&quot;exclude_headings_by_selector&quot;:[],&quot;headings_by_tags&quot;:[&quot;h2&quot;],&quot;marker_view&quot;:&quot;numbers&quot;,&quot;no_headings_message&quot;:&quot;No headings were found on this page.&quot;,&quot;hierarchical_view&quot;:&quot;yes&quot;,&quot;min_height&quot;:{&quot;unit&quot;:&quot;px&quot;,&quot;size&quot;:&quot;&quot;,&quot;sizes&quot;:[]},&quot;min_height_tablet&quot;:{&quot;unit&quot;:&quot;px&quot;,&quot;size&quot;:&quot;&quot;,&quot;sizes&quot;:[]},&quot;min_height_mobile&quot;:{&quot;unit&quot;:&quot;px&quot;,&quot;size&quot;:&quot;&quot;,&quot;sizes&quot;:[]}}" data-widget_type="table-of-contents.default">
				<div class="elementor-widget-container">
									<div class="elementor-toc__header">
						<h4 class="elementor-toc__header-title">
				Navigating the World of Calcium Indicators			</h4>
								</div>
				<div id="elementor-toc__1c2be94" class="elementor-toc__body">
			<div class="elementor-toc__spinner-container">
				<i class="elementor-toc__spinner eicon-animation-spin eicon-loading" aria-hidden="true"></i>			</div>
		</div>
						</div>
				</div>
				</div>
		<div class="elementor-element elementor-element-fdf7831 e-con-full e-flex e-con e-child" data-id="fdf7831" data-element_type="container">
				<div class="elementor-element elementor-element-01f1204 elementor-widget__width-initial elementor-widget-mobile__width-initial elementor-widget elementor-widget-text-editor" data-id="01f1204" data-element_type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
									<p><span id="docs-internal-guid-581ad719-7fff-5039-44e4-28fa7acd9a79"><span style="font-size: 12pt; font-family: Roboto, sans-serif; color: #0e101a; background-color: transparent; font-variant-numeric: normal; font-variant-east-asian: normal; font-variant-alternates: normal; font-variant-position: normal; vertical-align: baseline; white-space-collapse: preserve;">Calcium ions (Ca²⁺) are more than just nutrients for bone health; they are quintessential signaling molecules orchestrating a myriad of physiological processes at the cellular level. For researchers, unraveling these cellular mysteries begins with one crucial step: selecting the right calcium indicator. This guide is tailored to help you navigate this choice, ensuring you use the best tools to make the next groundbreaking discovery.</span></span></p>								</div>
				</div>
				</div>
				</div>
		<div class="elementor-element elementor-element-099da7c e-con-full e-flex e-con e-parent" data-id="099da7c" data-element_type="container" data-settings="{&quot;background_background&quot;:&quot;classic&quot;}">
				<div class="elementor-element elementor-element-4d192e3 elementor-widget elementor-widget-heading" data-id="4d192e3" data-element_type="widget" data-widget_type="heading.default">
				<div class="elementor-widget-container">
					<h2 class="elementor-heading-title elementor-size-default">Selecting the Right Indicator
</h2>				</div>
				</div>
		<div class="elementor-element elementor-element-60b879d e-con-full e-flex e-con e-child" data-id="60b879d" data-element_type="container" data-settings="{&quot;background_background&quot;:&quot;classic&quot;}">
				<div class="elementor-element elementor-element-4e7d5d7 elementor-widget elementor-widget-text-editor" data-id="4e7d5d7" data-element_type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
									<p><span style="font-weight: 400;">In the field of scientific research, the proper selection of a calcium indicator is crucial for obtaining reliable and meaningful data. This decision involves a detailed analysis of factors such as excitation and emission wavelengths, binding affinity for Ca²⁺, and the instrument(s) you are planning to use. These aspects are fundamental to ensure the quality of your experiments.</span></p>								</div>
				</div>
				<div class="elementor-element elementor-element-6ca5a71 elementor-widget elementor-widget-text-editor" data-id="6ca5a71" data-element_type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
									<p><span style="font-weight: 400;">The landscape of calcium indicators is extensive and varied, offering everything from widely used single-wavelength indicators to more quantitative, ratiometric indicators. Each type of indicator has specific advantages and limitations, and understanding these is essential to select the most suitable one for your needs.</span></p>								</div>
				</div>
				</div>
		<div class="elementor-element elementor-element-d8c3433 e-flex e-con-boxed e-con e-child" data-id="d8c3433" data-element_type="container">
					<div class="e-con-inner">
		<div class="elementor-element elementor-element-2ff8e17 e-con-full e-flex e-con e-child" data-id="2ff8e17" data-element_type="container">
				<div class="elementor-element elementor-element-1c74926 elementor-widget elementor-widget-text-editor" data-id="1c74926" data-element_type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
									<p><span style="letter-spacing: 0.4px;">Single wavelength indicators, such as Fluo-4, are known for their compatibility with a wide range of fluorescence instruments, and are the best choice for HTS and imaging fast signaling dynamics (calcium sparks in cardiomyocytes, neuronal calcium transients). Red shifted calcium indicators such as Fluo-gold and ICR-1 can be beneficial when multiplexing with GFP or other green dyes, may help avoid false positives when fluorescent compounds are in your screening library,  and can minimize autofluorescence from tissues. These indicators have been specifically designed to be compatible with existing instrumentation, making them a versatile option for various experimental setups.</span></p>								</div>
				</div>
				</div>
		<div class="elementor-element elementor-element-297b109 e-con-full e-flex e-con e-child" data-id="297b109" data-element_type="container">
				<div class="elementor-element elementor-element-7734fed elementor-widget elementor-widget-image" data-id="7734fed" data-element_type="widget" data-widget_type="image.default">
				<div class="elementor-widget-container">
															<img loading="lazy" decoding="async" width="800" height="523" src="https://ionbiosciences.com/wp-content/uploads/Calcium_indicators_Spectra_Figure-1024x669.png" class="attachment-large size-large wp-image-32324" alt="Excitation and emission spectra of ION’s fluorescent calcium indicators" srcset="https://ionbiosciences.com/wp-content/uploads/Calcium_indicators_Spectra_Figure-1024x669.png 1024w, https://ionbiosciences.com/wp-content/uploads/Calcium_indicators_Spectra_Figure-300x196.png 300w, https://ionbiosciences.com/wp-content/uploads/Calcium_indicators_Spectra_Figure-768x502.png 768w, https://ionbiosciences.com/wp-content/uploads/Calcium_indicators_Spectra_Figure-600x392.png 600w, https://ionbiosciences.com/wp-content/uploads/Calcium_indicators_Spectra_Figure.png 1296w" sizes="auto, (max-width: 800px) 100vw, 800px" />															</div>
				</div>
				</div>
					</div>
				</div>
		<div class="elementor-element elementor-element-f3e0b2d e-flex e-con-boxed e-con e-child" data-id="f3e0b2d" data-element_type="container">
					<div class="e-con-inner">
		<div class="elementor-element elementor-element-05aa0f2 e-con-full e-flex e-con e-child" data-id="05aa0f2" data-element_type="container">
				<div class="elementor-element elementor-element-d6e4184 elementor-widget elementor-widget-text-editor" data-id="d6e4184" data-element_type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
									<span style="letter-spacing: 0.4px;">On the other hand, in experiments requiring precise quantification of Ca²⁺, ratiometric indicators are indispensable. Ratiometric imaging with indicators like Fura-2 negates the effects of dye compartmentalization and sample thickness. Ratiometric indicators can also help resolve calcium concentrations within specific cellular compartments. However, their use requires specialized equipment, such as fluorescence microscopes or plate readers with rapid wavelength-switching capabilities, and more expensive glass bottom or poly-olefin plates that transmit UV light.</span>								</div>
				</div>
				</div>
		<div class="elementor-element elementor-element-e5b00e6 e-con-full e-flex e-con e-child" data-id="e5b00e6" data-element_type="container">
				<div class="elementor-element elementor-element-4b23c6c elementor-arrows-position-outside elementor-pagination-position-outside elementor-widget elementor-widget-image-carousel" data-id="4b23c6c" data-element_type="widget" data-settings="{&quot;slides_to_show&quot;:&quot;1&quot;,&quot;navigation&quot;:&quot;both&quot;,&quot;autoplay&quot;:&quot;yes&quot;,&quot;pause_on_hover&quot;:&quot;yes&quot;,&quot;pause_on_interaction&quot;:&quot;yes&quot;,&quot;autoplay_speed&quot;:5000,&quot;infinite&quot;:&quot;yes&quot;,&quot;effect&quot;:&quot;slide&quot;,&quot;speed&quot;:500}" data-widget_type="image-carousel.default">
				<div class="elementor-widget-container">
							<div class="elementor-image-carousel-wrapper swiper" role="region" aria-roledescription="carousel" aria-label="Image Carousel" dir="ltr">
			<div class="elementor-image-carousel swiper-wrapper" aria-live="off">
								<div class="swiper-slide" role="group" aria-roledescription="slide" aria-label="1 of 2"><a data-elementor-open-lightbox="yes" data-elementor-lightbox-slideshow="4b23c6c" data-e-action-hash="#elementor-action%3Aaction%3Dlightbox%26settings%3DeyJpZCI6MTExNzMsInVybCI6Imh0dHBzOlwvXC9pb25iaW9zY2llbmNlcy5jb21cL3dwLWNvbnRlbnRcL3VwbG9hZHNcL2Z1cmEtMi1yYXRpb21ldHJpYy1taWNyb3Njb3B5LnBuZyIsInNsaWRlc2hvdyI6IjRiMjNjNmMifQ%3D%3D" href="https://ionbiosciences.com/wp-content/uploads/fura-2-ratiometric-microscopy.png"><figure class="swiper-slide-inner"><img decoding="async" class="swiper-slide-image" src="https://ionbiosciences.com/wp-content/uploads/fura-2-ratiometric-microscopy.png" alt="Ratiometric images of Fura-2 AM loaded cells before and after the addition of ionomycin, which causes an influx of calcium into the cells that&#039;s reported as a higher ratio of bound/unbound Fura-2 fluorescence." /></figure></a></div><div class="swiper-slide" role="group" aria-roledescription="slide" aria-label="2 of 2"><a data-elementor-open-lightbox="yes" data-elementor-lightbox-slideshow="4b23c6c" data-e-action-hash="#elementor-action%3Aaction%3Dlightbox%26settings%3DeyJpZCI6ODcwMywidXJsIjoiaHR0cHM6XC9cL2lvbmJpb3NjaWVuY2VzLmNvbVwvd3AtY29udGVudFwvdXBsb2Fkc1wvZnVyYS0yLWNhbGNpdW0tYXNzYXkta2luZXRpYy5wbmciLCJzbGlkZXNob3ciOiI0YjIzYzZjIn0%3D" href="https://ionbiosciences.com/wp-content/uploads/fura-2-calcium-assay-kinetic.png"><figure class="swiper-slide-inner"><img decoding="async" class="swiper-slide-image" src="https://ionbiosciences.com/wp-content/uploads/fura-2-calcium-assay-kinetic.png" alt="Sample data showing kinetic fluorescence data of fura-2 AM (bound and unbound) in response to calcium influx with the corresponding fluorescence ratio plotted separately." /></figure></a></div>			</div>
												<div class="elementor-swiper-button elementor-swiper-button-prev" role="button" tabindex="0">
						<i aria-hidden="true" class="eicon-chevron-left"></i>					</div>
					<div class="elementor-swiper-button elementor-swiper-button-next" role="button" tabindex="0">
						<i aria-hidden="true" class="eicon-chevron-right"></i>					</div>
				
									<div class="swiper-pagination"></div>
									</div>
						</div>
				</div>
				</div>
					</div>
				</div>
				</div>
		<div class="elementor-element elementor-element-a70e2bb e-con-full e-flex e-con e-parent" data-id="a70e2bb" data-element_type="container" data-settings="{&quot;background_background&quot;:&quot;classic&quot;}">
				<div class="elementor-element elementor-element-178ff9b elementor-widget elementor-widget-heading" data-id="178ff9b" data-element_type="widget" data-widget_type="heading.default">
				<div class="elementor-widget-container">
					<h2 class="elementor-heading-title elementor-size-default">Indicator Formats and Supporting Reagents
</h2>				</div>
				</div>
		<div class="elementor-element elementor-element-d62538c e-flex e-con-boxed e-con e-child" data-id="d62538c" data-element_type="container">
					<div class="e-con-inner">
		<div class="elementor-element elementor-element-f0216a6 e-con-full e-flex e-con e-child" data-id="f0216a6" data-element_type="container">
				<div class="elementor-element elementor-element-fca031b elementor-widget elementor-widget-text-editor" data-id="fca031b" data-element_type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
									<p><span style="font-weight: 400;">The choice between salts and AM esters is critical. Salts, being the active form of our dyes, are cell-impermeable, making them suitable for extracellular measurements and solid-state sensing. Conversely, AM esters help facilitate the entry of negatively charged Ca²⁺ indicators into cells by masking their charges, and they only become active once inside the cell when these AM esters are cleaved by endogenously expressed esterases. Once activated, indicators are no longer able to passively cross, or leak out, of the cellular membrane. </span></p>								</div>
				</div>
				</div>
		<div class="elementor-element elementor-element-14908a3 e-con-full e-flex e-con e-child" data-id="14908a3" data-element_type="container">
				<div class="elementor-element elementor-element-5c50df6 elementor-widget__width-initial elementor-widget elementor-widget-image" data-id="5c50df6" data-element_type="widget" data-widget_type="image.default">
				<div class="elementor-widget-container">
																<a href="https://ionbiosciences.com/wp-content/uploads/dye-salts-and-esters.png" data-elementor-open-lightbox="yes" data-e-action-hash="#elementor-action%3Aaction%3Dlightbox%26settings%3DeyJpZCI6MzI0ODAsInVybCI6Imh0dHBzOlwvXC9pb25iaW9zY2llbmNlcy5jb21cL3dwLWNvbnRlbnRcL3VwbG9hZHNcL2R5ZS1zYWx0cy1hbmQtZXN0ZXJzLnBuZyJ9">
							<img loading="lazy" decoding="async" width="1297" height="847" src="https://ionbiosciences.com/wp-content/uploads/dye-salts-and-esters.png" class="elementor-animation-grow attachment-full size-full wp-image-32480" alt="Images of an ion indicator in the salt form and as an AM ester" srcset="https://ionbiosciences.com/wp-content/uploads/dye-salts-and-esters.png 1297w, https://ionbiosciences.com/wp-content/uploads/dye-salts-and-esters-300x196.png 300w, https://ionbiosciences.com/wp-content/uploads/dye-salts-and-esters-1024x669.png 1024w, https://ionbiosciences.com/wp-content/uploads/dye-salts-and-esters-768x502.png 768w, https://ionbiosciences.com/wp-content/uploads/dye-salts-and-esters-600x392.png 600w" sizes="auto, (max-width: 1297px) 100vw, 1297px" />								</a>
															</div>
				</div>
				</div>
					</div>
				</div>
		<div class="elementor-element elementor-element-655709e e-flex e-con-boxed e-con e-child" data-id="655709e" data-element_type="container">
					<div class="e-con-inner">
				<div class="elementor-element elementor-element-863d41e elementor-widget__width-initial elementor-widget-tablet__width-initial elementor-widget elementor-widget-image" data-id="863d41e" data-element_type="widget" data-widget_type="image.default">
				<div class="elementor-widget-container">
																<a href="https://ionbiosciences.com/wp-content/uploads/Captura-de-pantalla-2024-02-13-094306.png" data-elementor-open-lightbox="yes" data-e-action-hash="#elementor-action%3Aaction%3Dlightbox%26settings%3DeyJpZCI6MzI0ODIsInVybCI6Imh0dHBzOlwvXC9pb25iaW9zY2llbmNlcy5jb21cL3dwLWNvbnRlbnRcL3VwbG9hZHNcL0NhcHR1cmEtZGUtcGFudGFsbGEtMjAyNC0wMi0xMy0wOTQzMDYucG5nIn0%3D">
							<img loading="lazy" decoding="async" width="900" height="559" src="https://ionbiosciences.com/wp-content/uploads/Captura-de-pantalla-2024-02-13-094306.png" class="attachment-full size-full wp-image-32482" alt="Images of ion indicator loaded cells with and without an MDR inhibitor" srcset="https://ionbiosciences.com/wp-content/uploads/Captura-de-pantalla-2024-02-13-094306.png 900w, https://ionbiosciences.com/wp-content/uploads/Captura-de-pantalla-2024-02-13-094306-300x186.png 300w, https://ionbiosciences.com/wp-content/uploads/Captura-de-pantalla-2024-02-13-094306-768x477.png 768w, https://ionbiosciences.com/wp-content/uploads/Captura-de-pantalla-2024-02-13-094306-600x373.png 600w" sizes="auto, (max-width: 900px) 100vw, 900px" />								</a>
															</div>
				</div>
		<div class="elementor-element elementor-element-3049f44 e-con-full e-flex e-con e-child" data-id="3049f44" data-element_type="container" data-settings="{&quot;background_background&quot;:&quot;classic&quot;}">
				<div class="elementor-element elementor-element-e05e8fd elementor-widget elementor-widget-text-editor" data-id="e05e8fd" data-element_type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
									<p><span style="font-weight: 400;">However, retaining these indicators within cells is complicated by the activity of multidrug resistance (MDR) transporters. These proteins actively transport drugs, dyes, and other compounds from the inside of cells to the extracellular space. Certain cell types (e.g. CHOs) express significantly higher levels of MDR transporters than others, making long-term imaging experiments difficult. Using inhibitors like probenecid can significantly improve cytoplasmic localization and retention, leading to brighter and sustained signals in assays.</span></p>								</div>
				</div>
				</div>
					</div>
				</div>
				<div class="elementor-element elementor-element-3a8f0ed elementor-widget elementor-widget-text-editor" data-id="3a8f0ed" data-element_type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
									<p><span style="font-weight: 400;">The hydrophobic nature of AM indicators can impact the efficiency of loading them into cells. In this context, Pluronic F-127, a surfactant, plays an essential role. It enhances the solubility of the indicators in aqueous solvents, ensuring better dye transport across the membrane and more consistent loading.</span></p>								</div>
				</div>
				</div>
		<div class="elementor-element elementor-element-d4b488c e-con-full e-flex e-con e-parent" data-id="d4b488c" data-element_type="container" data-settings="{&quot;background_background&quot;:&quot;classic&quot;}">
				<div class="elementor-element elementor-element-437b7bf elementor-widget elementor-widget-heading" data-id="437b7bf" data-element_type="widget" data-widget_type="heading.default">
				<div class="elementor-widget-container">
					<h2 class="elementor-heading-title elementor-size-default">Applications and Compatibility
</h2>				</div>
				</div>
		<div class="elementor-element elementor-element-148f043 e-flex e-con-boxed e-con e-child" data-id="148f043" data-element_type="container">
					<div class="e-con-inner">
		<div class="elementor-element elementor-element-fd400f6 e-con-full e-flex e-con e-child" data-id="fd400f6" data-element_type="container" data-settings="{&quot;background_background&quot;:&quot;classic&quot;}">
		<div class="elementor-element elementor-element-fcbb0fa e-con-full e-flex e-con e-child" data-id="fcbb0fa" data-element_type="container" data-settings="{&quot;background_background&quot;:&quot;classic&quot;}">
				<div class="elementor-element elementor-element-7551e81 elementor-widget elementor-widget-text-editor" data-id="7551e81" data-element_type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
									<p><span style="font-weight: 400;">Calcium-sensitive fluorescent indicators are compatible with a broad array of detection equipment, including fluorescent microscopes, plate readers, flow cytometers, and indicator-doped solid-state sensors. This versatility is essential to meet the specific needs of various types of research.</span></p>								</div>
				</div>
				<div class="elementor-element elementor-element-328301e elementor-widget elementor-widget-text-editor" data-id="328301e" data-element_type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
									<span style="font-weight: 400;">Over the past three decades, Ca²⁺-sensitive indicators have played a critical role in diverse research applications. They have significantly contributed to our understanding of cellular signaling and beyond, from high-resolution imaging of synaptic activity to high-throughput measurements of G<sub>q</sub> GPCRs and calcium channels in drug discovery.</span>								</div>
				</div>
				</div>
				<div class="elementor-element elementor-element-6d4b5f0 elementor-widget elementor-widget-text-editor" data-id="6d4b5f0" data-element_type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
									<p><span style="font-weight: 400;">Choosing the right calcium indicator is a pivotal decision in your research. The correct choice can make the difference between an experiment that merely indicates trends and one that provides meaningful insights. As you embark on or continue your cellular research, let this guide be your compass, leading you to the appropriate indicators that will illuminate your discovery journey.</span></p><p><span style="font-weight: 400;">We invite you to explore our website for product specific information and reach out to our experts with any inquiries you may have about which products are most suitable for your needs.</span></p>								</div>
				</div>
				</div>
					</div>
				</div>
				</div>
		<div class="elementor-element elementor-element-725aa85 e-con-full e-flex e-con e-parent" data-id="725aa85" data-element_type="container" data-settings="{&quot;background_background&quot;:&quot;classic&quot;}">
				<div class="elementor-element elementor-element-0c11bf2 elementor-widget__width-initial elementor-widget-mobile__width-initial elementor-widget elementor-widget-text-editor" data-id="0c11bf2" data-element_type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
									<p><span style="font-weight: 400;">We invite you to explore our website for product specific information and <a href="https://ionbiosciences.com/contact/">reach out to our experts</a> with any inquiries you may have about which products are most suitable for your needs.</span></p>								</div>
				</div>
				</div>
				</div>
		]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
